Capacitor Banks

SuperBANKS

Capacitors are a fantastic solution for everyday electronics. From commercial use to custom-tailored solutions, capacitors aid in stabilizing voltage when you need it most. Capacitors are designed to deliver instant current based on the demand, which eliminates voltage sag when a load is applied. This means your voltage maintains stability for your electronics, allowing higher efficiency for your application.

XS Power SuperBANK, group 31 case
75 – 1500F
Capacitance range
20+ sizes
Case and group fits
Instant
Current on demand
No sag
Voltage stability

Why A SuperBANK

A bank of capacitors does one thing a battery cannot: deliver current the instant it is asked for. Here is what that changes in the system.

01

Instant current on demand

A capacitor answers a load in milliseconds, before the battery or alternator has time to respond.

02

No voltage sag

Voltage holds steady when the load hits, which is what the rest of the electrical system is built to expect.

03

Higher system efficiency

Stable voltage means amplifiers and electronics run at the operating point they were designed around.

04

Works with any battery

A bank sits in parallel with whatever is already installed, lead or lithium, and does not change the charging setup.

05

Sized by the case

Over twenty case sizes, from a group 75 down to a powersports Q, so the bank fits the space that exists.

06

Built for commercial use

The same banks are used in commercial and custom applications, not only in audio installs.

Find Your Size

SuperBANKS are sold by the case they fit, not by series. Start from the size in the vehicle and pick the capacitance you want inside it.

Group 27 SuperBANK
BCI automotive

Group 27

Full-size automotive case. The largest banks in a footprint most trucks and vans already have a tray for.

SB1260-27SB1000-27SB500-27
Shop Group 27 →
Most popularGroup 31 SuperBANK
BCI automotive

Group 31

The commercial standard case, and the size that holds the widest range of capacitance in the line.

SB1260-31US1100-31SB1050-31SB1000-31
Shop Group 31 →
Group 34 SuperBANK
BCI automotive

Group 34

The most common passenger-car footprint. Drops into the factory tray with the stock hold-down.

SB630-34SB500-34SB500-34R
Shop Group 34 →
Group 51 SuperBANK
BCI automotive

Group 51

Compact import case, in standard and reversed-terminal versions.

SB630-51SB630-51RSB500-51SB500-51R
Shop Group 51 →
LargestGroup 75 SuperBANK
BCI automotive

Group 75

Side-terminal case carrying the biggest bank we build, at 1500 farads.

SB1500-75SB1000-75
Shop Group 75 →
Group 65 SuperBANK
BCI automotive

Group 65

Domestic truck and SUV case for stabilizing high accessory loads.

SB500-65
Shop Group 65 →
Groups 47 48 49 SuperBANK
BCI automotive

Groups 47 / 48 / 49

European DIN cases in three lengths, so late-model imports keep the factory mounting.

SB500-47SB500-48SB500-49
Shop 47 / 48 / 49 →
Groups 16 24 SuperBANK
BCI automotive

Groups 16 / 24

Tall-case fits for older domestic and import platforms.

SB500-24SB430-16
Shop 16 / 24 →
Q case SuperBANK
Powersports

Q Cases

Powersports footprints for UTVs, bikes and sleds where the electrical system is small but the loads spike hard.

SB150-30QSB75-30QSB75-20QSB75-14Q
Shop Q Cases →
L case SuperBANK
Compact / racing

L Cases

Low-profile cases for tight installs and race cars carrying minimum weight.

SB150-975LSB150-925LSB75-975LSB75-925LSB75-680LSB75-545L
Shop L Cases →
Group 5 SuperBANK
Compact / racing

Group 5

The smallest bank in the line, available on its own or as a mounted kit.

SB75-5SB75-5CK
Shop Group 5 →
1200 case SuperBANK
Compact / racing

1200 Case

Race-oriented case sized to sit alongside a 16V pack rather than replace it.

SB630-1200
Shop 1200 Case →
CellsSuperCELL 33-Series
Cells

SuperCELL 33-Series

Individual cells for building or repairing a bank to your own specification.

33-120033-1100
Shop SuperCELL →

Sizes At A Glance

Size Fits Capacitance Part numbers
Group 27 Full-size automotive 500 – 1260F SB1260-27, SB1000-27, SB500-27
Group 31 Commercial standard 1000 – 1260F SB1260-31, US1100-31, SB1050-31, SB1000-31
Group 34 Passenger car 500 – 630F SB630-34, SB500-34, SB500-34R
Group 51 Compact import 500 – 630F SB630-51, SB630-51R, SB500-51, SB500-51R
Group 75 Side terminal 1000 – 1500F SB1500-75, SB1000-75
Group 65 Domestic truck / SUV 500F SB500-65
Groups 47 / 48 / 49 European DIN 500F SB500-47, SB500-48, SB500-49
Groups 16 / 24 Tall case 430 – 500F SB500-24, SB430-16
Q cases Powersports 75 – 150F SB150-30Q, SB75-30Q, SB75-20Q, SB75-14Q
L cases Compact / racing 75 – 150F SB150-975L, SB75-975L, SB75-680L, SB75-545L
Group 5 Smallest fit 75F SB75-5, SB75-5CK
1200 case Racing 630F SB630-1200
SuperCELL Cells for custom banks 1100 – 1200F 33-1200, 33-1100

Capacitor vs. Battery

A SuperBANK is not a replacement for storage. It is the part of the system that answers first.

XS Power SB1500-75
XS Power SB1500-75
SuperBANK
Delivers current in milliseconds
Battery
Responds over seconds under load
SuperBANK
Holds voltage flat during a spike
Battery
Sags, then recovers
SuperBANK
Very little stored energy
Battery
Stores the energy the vehicle runs on
SuperBANK
Hundreds of thousands of cycles
Battery
Cycle life measured in hundreds to thousands
SuperBANK
Installs in parallel, no charging change
Battery
Charging profile matched to chemistry

Common Questions

What does a capacitor bank actually do?

It delivers current the instant a load asks for it, so the system voltage does not dip while the battery and alternator catch up. That is what keeps lights steady and amplifiers clean when the demand spikes.

Does a SuperBANK replace my battery?

No. A capacitor holds very little energy compared to a battery. It handles the instant demand; the battery still handles storage and starting.

How do I pick a size?

Start with the case that fits the space you have, then choose the capacitance in that case. Part numbers read as farads first, case second: SB1260-31 is 1260 farads in a group 31 case.

Do I need anything else to install one?

Standard battery cable and a solid mounting point. The bank connects in parallel with the battery, as close to the load as the install allows.

What is the difference between a SuperBANK and a SuperCELL?

A SuperBANK is a finished, cased bank ready to install. SuperCELLs are individual cells for building or repairing a bank yourself.

Not sure which size fits?

Tell us the case you have to work with and the load you are stabilizing.